Icon Equipment

  • 3028 W Lincoln St
  • Phoenix, AZ 85009
  • Call Us: (623) 401-4266
  • https://www.icon-equip.com/
Print This Page

2025 Kubota Engines GL Series 14000

Information

2025 Kubota Engines GL Series 14000

GL Series

Features may include:

  • Prime Output 12 kVA
  • Standby Output 14 kVA
  • Frequency: 60 HZ
  • Phase: Single
  • Generator and engine are direct-coupled to ensure a more reliable power supply with minimum power loss.
  • Large-capacity fuel tank (36.4L / 9.62 U.S gal.) enables longer continuous operation on a single tank.

Easy Maintenance

  • One-side maintenance to reduce the operator’s work load.
  • Larger-capacity oil pan employed to stretch the oil change intervals up to 200 operating hours. Reduces the running cost for the generator owner.

Safety Features

  • Protective covers on all moving parts (for the engine’s cooling fan and the generator).
  • Automatically shuts the engine down in case the water temperature rises excessively or the oil pressure drops below a safe level.

Wide Application

  • Double element air cleaners are standard equipment. Ideal for heavy-duty application in dusty environments.
  • An access terminal to connect to the ATS (Automatic Transfer Switches) is standard equipment. Applicable for stationary use as well.

Photos

Highlights

  • Phoenix, Arizona
  • 2025
  • Kubota Engines
  • GL Series 14000
  • Model: D902
  • Net: 904 lbs. (410 kg) / 1003 lbs. (455 kg)
  • Available
  • 25.2 in. (640 mm)
  • 35.24 in. (895 mm)

Specifications

  • 2025
  • Kubota Engines
  • GL Series
  • 14000
  • General
  • Model: D902
  • Kubota
  • 3600 rpm
  • EPA Tier 4 Final, CARB
  • 1.29 gal./h (4.9 L/h) | At 3/4 Load: 1.03 gal./h (3.9 L/h) | At 1/2 Load: 0.85 gal./h (3.2 L/h) | At: 1/4 Load: 0.66 gal./h (2.5 L/h)
  • Frequency: 60 Hz | Rated Voltage: 240 / 120 V | Rated Current: 100 A | Phase / Wire: 1-3 | Power Factor: 1.0 | Frequency Regulation: 0.25 % | Voltage Regulation: 240V: ±0.5 / 120V: ±5.0 % | Voltage Adjusting Range: -15%~+5% of the rated voltage | Momentary Load Variability % Fluctuation rate of the maximum voltage: 30% / Within 3% of the setting voltage Recovery time: 2 seconds | Waveform Distortion Factor (at no load): 2.0 % | Minimum Insulation Resistance: 3 Ohm | Withstand Voltage Test Procedure: 1500V, within 1 minute
  • Rated: 12 kVA | Maximum: 14 kVA | Terminal Block: Single phase - 3 wires (U-N/G-W) / Terminal Size: M8
  • 120V-20A GFCI x 2 (4 receptacles) / 120/240V-50A Twist type x 1
  • Full Load: 7.0 h | At 3/4 Load: 9.0 h | At 1/2 Load: 11.0 h | At: 1/4 Load: 15.0 h
  • Noise Level (No Load / Rated Operation): 65 / 67 (dB • A/7 m)
  • Engine Shut-Off: Low Oil Pressure, Excessive Coolant Temperature, Improper Charging, Over Revolution | Emergency Stop System: Opening of control panel or terminal cover
  • 51.57 in. (1310 mm)
  • 25.2 in. (640 mm)
  • 35.24 in. (895 mm)
  • Spill Containment Capacity: 82 L (186% of the entire fuel, oil and coolant)
  • 9.62 gal. (36.4 L)
  • Net: 904 lbs. (410 kg) / 1003 lbs. (455 kg)
  • Breaker: Main x 1 Secondary In-line x2