2025 Kubota Engines GL Series 14000
- Year 2025
- Make Kubota Engines
- Model GL Series
- Engine Model: D902
2025 Kubota Engines GL Series 14000
GL Series
Features may include:
- Prime Output 12 kVA
- Standby Output 14 kVA
- Frequency: 60 HZ
- Phase: Single
- Generator and engine are direct-coupled to ensure a more reliable power supply with minimum power loss.
- Large-capacity fuel tank (36.4L / 9.62 U.S gal.) enables longer continuous operation on a single tank.
Easy Maintenance
- One-side maintenance to reduce the operator’s work load.
- Larger-capacity oil pan employed to stretch the oil change intervals up to 200 operating hours. Reduces the running cost for the generator owner.
Safety Features
- Protective covers on all moving parts (for the engine’s cooling fan and the generator).
- Automatically shuts the engine down in case the water temperature rises excessively or the oil pressure drops below a safe level.
Wide Application
- Double element air cleaners are standard equipment. Ideal for heavy-duty application in dusty environments.
- An access terminal to connect to the ATS (Automatic Transfer Switches) is standard equipment. Applicable for stationary use as well.
Engine
Engine Manufacturer
Kubota
Engine
Model: D902
Rated Engine Speed
3600 rpm
Emissions
EPA Tier 4 Final, CARB
Fuel System
Fuel Usage, 100% Load
1.29 gal./h (4.9 L/h) | At 3/4 Load: 1.03 gal./h (3.9 L/h) | At 1/2 Load: 0.85 gal./h (3.2 L/h) | At: 1/4 Load: 0.66 gal./h (2.5 L/h)
Electric
Electrical
Frequency: 60 Hz | Rated Voltage: 240 / 120 V | Rated Current: 100 A | Phase / Wire: 1-3 | Power Factor: 1.0 | Frequency Regulation: 0.25 % | Voltage Regulation: 240V: ±0.5 / 120V: ±5.0 % | Voltage Adjusting Range: -15%~+5% of the rated voltage | Momentary Load Variability % Fluctuation rate of the maximum voltage: 30% / Within 3% of the setting voltage Recovery time: 2 seconds | Waveform Distortion Factor (at no load): 2.0 % | Minimum Insulation Resistance: 3 Ohm | Withstand Voltage Test Procedure: 1500V, within 1 minute
Generator Output
Rated: 12 kVA | Maximum: 14 kVA | Terminal Block: Single phase - 3 wires (U-N/G-W) / Terminal Size: M8
Receptacles
120V-20A GFCI x 2 (4 receptacles) / 120/240V-50A Twist type x 1
Operational
Run Time Per Tankful
Full Load: 7.0 h | At 3/4 Load: 9.0 h | At 1/2 Load: 11.0 h | At: 1/4 Load: 15.0 h
Performance
Noise Level
Noise Level (No Load / Rated Operation): 65 / 67 (dB • A/7 m)
Lights and Safety
Safety Features
Engine Shut-Off: Low Oil Pressure, Excessive Coolant Temperature, Improper Charging, Over Revolution | Emergency Stop System: Opening of control panel or terminal cover
Dimensions
Length
51.57 in. (1310 mm)
Width
25.2 in. (640 mm)
Height
35.24 in. (895 mm)
Capacities
Oil capacity
Spill Containment Capacity: 82 L (186% of the entire fuel, oil and coolant)
Fuel Capacity
9.62 gal. (36.4 L)
Weights
Dry Weight
Net: 904 lbs. (410 kg) / 1003 lbs. (455 kg)
Features
Features
Breaker: Main x 1 Secondary In-line x2